4
4-14
Eclipse™ 2640 SAN Router Administration and Configuration Manual
Configuring iFCP Connections
Configuring iFCP Connections
To configure an iFCP connection, configure a TCP port (13-16) as
iFCP, as described in
Configuring TCP Ports for iFCP on page 4-4. A
pair of SAN Routers connects two mSANs. Each mSAN is identified
by a unique mSAN ID and each has its own mSNS. Only configure a
mSAN ID when iFCP is being used. Otherwise, there is only a single
mSAN.
To configure the SAN Router for iFCP connections, select the
following options from the Configuration>iFCP tab:
•Select Setup to configure the mSAN ID for the iFCP function.
•Select Remote Connections to configure connection-specific
parameters. refer to
Configure Remote iFCP Connections on
page 4-15.
Configuring iFCP Setup
To configure the SAN Router for iFCP connection, follow these
instructions:
1. Select Configuration>iFCP>Setup to display the iFCP Setup dialog
box (
Figure 4-5).
Figure 4-5 iFCP Setup Dialog Box
2. Optionally, change the Active on next reset mSAN ID.
A new mSAN ID takes effect when you reset the system. Thus,
two IDs are shown: the ID currently in effect and the ID that
will be used after you reset the system.