3
3-44
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
b. At the EFCM Basic Edition interface or SAN management
application, inspect names in the active zone set to determine
the incompatible zone name, then modify the name as directed
by the customer:
EFCM Basic Edition - Refer to the McDATA EFCM Basic
Edition User Manual (620-000240) for instructions.
SAN management application - Refer to the EFC Manager
Software Release 8.7 User Manual (620-000170) for
instructions.
Was the maintenance action successful?
NO YES
The fabric, ISL, and product are operational. Exit MAP.
Contact the next level of support. Exit MAP.
11
An E_Port segmented because a build fabric protocol error was
detected.
a. Disconnect the fiber-optic jumper cable from the segmented
E_Port.
b. Reconnect the cable to the same port.
Was the maintenance action successful?
NO YES
The fabric, ISL, and product are operational. Exit MAP.
12
Reset the product. Refer to IML or Reset Switch for instructions.
Was the maintenance action successful?
NO YES
The fabric, ISL, and product are operational. Exit MAP.
Perform a data collection and contact the next level of support. Refer
to Collecting Maintenance Data (EFCM Basic Edition) or Collecting
Maintenance Data (Element Manager). Exit MAP.