Sun StorEdge Network 2 Gb McData Intrepid 6140 Director Release Notes 5
■ Bug 4837556 (P4/S4): In a two-host fabric, if each host is connected to a different
switch, a ping reports “no answer from IP-address.”
Workaround: This is actually a request for enhancement (RFE) and there is no
workaround at this time.
■ Bug 4850918 (P4/S2): The 6140 director become inaccessible to the McDATA
Enterprise Fabric Connectivity Management (EFCM) Lite software.
The McDATA 4500 switch and 6064 and 6140 directors use a Network
Management Request/Response Unit (NMRU) connection for management
purposes. Since only one NMRU session is allowed at any given time, if the Sun
StorEdge Enterprise Storage Manager (ESM) software takes the NMRU
connection, then the EFCM Lite software cannot connect to the 4500 switch.
Workaround: Do not run ESM and EFCM Lite software simultaneously to
manage or monitor the fabric.
■ Bug 4854365 (P3/S3): An “Invalid Attachment” port state is reported on the 6140
or 4500 switch.
Workaround: Use only Sun-approved host bus adapters (HBAs).
■ Bug 4859897 (P3/S4): When merging McDATA fabrics (for example, adding a
fabric with a McDATA 4500 switch to a McDATA 6064 switch fabric), the
McDATA Enterprise Fabric Connectivity Management (EFCM) Lite software can
report the first interswitch link (ISL—links between cascaded switches) segments
with zone mismatch error if there are zones with the same name/identifier in
both switches.
When the principle ISL in a McDATA switch fabric segments, the initiators might
not be able to communicate with all the target devices.
Workaround: Use the EFCM Lite to rename the zones in the fabric so that all
zones have unique names before merging the fabrics.