McDATA Intrepid 6140 Director Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
6 Sun StorEdge Network 2 Gb McDATA Intrepid 6140 Director Release Notes July 2003
Bugs With System Components Configured With
the 6140 Director
Bug 4747435 (P2/S2): When issuing the cfgadm command, an I/O failure occurs
and the output reports the Sun StorEdge T3 array in an unusable state.
Workaround: Check the integrity of the 6140 director port cable connections and
verify that the green port LEDs are lit.
Bug 4811576 (P3/S1): When disconnecting a cable from the host to a 6140 director
and reconnecting it to another 6140 director within the same fabric (using WWN
zoning), the host stops functioning.
Workaround: Stop all I/O processes before removing the HBA cables.
Bug 4749906 (P2/S2): If a configuration uses extended distances (10 kilometers),
the host HBA might cycle offline/online repeatedly.
Workaround: Do not use links of 10 kilometers.
Bug 4744293 (P2/S2): The hosts cannot ping each other with FCIP configured.
Workaround: Do not use interswitch links (ISLs) with the Sun StorEdge Network
2 Gb Fibre Channel Switch-8 and Switch-16. If no ISLs are involved, try a few
plumb/unplumb operations.
Bug 4715673 (P3/S2): Any slicd (daemon) command fails when submitted in
succession in the background.
Workaround:
Issue only one slicd command at a time.
Issue the command in the foreground.
Bug 4756241 (P3/S3): The qlc firmware reports system error message 8002. The
HBA resets and results in an offline/online message.
Workaround: Be aware that this problem can occur and ignore the message.
# cfgadm -al c4
Ap_Id Type Receptacle Occupant Condition
c5::50020f230000bfed disk connected configured unusable
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios