Maintenance Analysis Procedures
3-39
Maintenence Analysis Procedures
If the port is operational with no device attached, both LEDs
adjacent to the port extinguish and the port state is
No Light
.
If the port is operational with a device attached, the blue/green
LED illuminates, the amber LED extinguishes, and the port state
is
Online
.
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
8
An ISL connection is not allowed because E_Port capability is
disabled. Install the full-fabric PFE key to enable E_port capability
(
Task 16: Configure PFE Key (Optional)
on page 2-51 and
Install PFE
Keys (Optional)
on page 2-25). Exit MAP.
9
The connection timed out because of an unresponsive device or an
ISL security violation (authorization failure reject). Check port status
and clean fiber-optic components.
a. Inform the customer the port will be blocked. Ensure the system
administrator quiesces Fibre Channel frame traffic and sets
attached devices offline.
b. Block the port (
Blocking and Unblocking Ports
on page 4-27).
c. Clean fiber-optic connectors (
Cleaning Fiber-Optic Components
on page 4-40.
d. Unblock the port (
Blocking and Unblocking Ports
on page 4-27).
e. Monitor port operation for approximately five minutes.
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
10
Inspect and service host bus adapters (HBAs).
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.