McDATA 1U Server Manual de servicio Pagina 327

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 430
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 326
A
Fan Module Events (300 through 399)
A-33
Event Code Tables
Event Code: 310
Message: Cooling fan propeller recovered.
Severity: Informational.
Explanation: One cooling fan recovered or the associated fan module was replaced. One fan is operational.
Action: No action required.
Event Data: The first byte of event data (byte 0) specifies the recovered fan number.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 311
Message: Cooling fan propeller recovered.
Severity: Informational.
Explanation: Two cooling fans recovered or the associated fan modules were replaced. Two fans are operational.
Action: No action required.
Event Data: The first byte of event data (byte 0) specifies the recovered fan numbers.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
Vista de pagina 326
1 2 ... 322 323 324 325 326 327 328 329 330 331 332 ... 429 430

Comentarios a estos manuales

Sin comentarios