A
Port Card (UPM and XPM) Events (500 through 599)
A-49
Event Code Tables
Port Card (UPM and XPM) Events (500 through 599)
Event Code: 500
Message: Port card hot-insertion initiated.
Severity: Informational
Explanation: Installation of a UPM was initiated with the director powered on and operational. The event indicates that
operational firmware detected the presence of the UPM, but the card is not seated. When the card is seated in
the director chassis and identified by firmware, an event code 501 is generated.
Action: If event code 501 follows this event and the amber LED on the UPM extinguishes, the replacement card is
installed and no additional action is required. If event code 501 does not follow this event, re-seat the UPM. If
event code 501 still does not appear, replace the UPM.
Event Data: Byte 0 = UPM slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 501
Message: Port card recognized.
Severity: Informational.
Explanation: A UPM is installed and recognized by director operational firmware.
Action: No action required.
Event Data: Byte 0 = UPM slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident